QUANTUMUSER MANUALCleveland Motion ControlsMAN-70421
10EntEnt1– SET POINT Setting 4– System General Settings2–Variable SettingHold for increase Hold for decrease Ent•Press both buttons simultaneouslyto e
displaylanguagefrench Ninputsunitsenglish kgregulation typedisplay config.italiano lbfunctionsdeutsch NmoutputsPLImemoriesmeasureFtlbdiameter%line 1ml
www.cmccontrols.comtime delay start duration (* 10ms)1time delay stopE-stop option duration (* 10ms)1no-stophold fixed fixed0taperproportional enable
13PC SOFTWARE - INSTALLATION AND USEThe CD-Rom delivered with your box contains a PC software dedicated to the QUANTUM, calledQUANTUMsoft.Launch the “
NOTESwww.cmccontrols.com14
151.0Parameter1.1 Communicate parameters to regulatorSave or load a set of parameters on the PCTo save a set of parameters, click in the thumb index
www.cmccontrols.com16Parameter1.2 Begin a new parameter settingChoose the type of parameter settingBefore beginning a new parameter setting, you must
172.0Menu INPUTS 2.1 Measure MenuThis menu appears when choosing closed loop, inertia correction,motor command or speedfollower. It allows calibratio
www.cmccontrols.com18Menu INPUTS 2.2 Set Point MenuTwo types of set points are available-Internal set point: type in the chosen value, it can be modi
19Menu INPUTS 2.3 Diameter MenuDiameter calibrationWith an analog diameter measure, the signal must be calibrated from physical values (upper point=
www.cmccontrols.comCongratulations on your Cleveland MotionControls Quantum digital controller!You have just acquired the most user friendlyand powerf
www.cmccontrols.com20Menu INPUTS 2.2 FILTERINGAll the inputs can be filtered. Filtering makes the regulation less sensitive to electric andmechanical
213.0 Menu DISPLAY 3.1 Units / DisplayThe front panel is used to display measurement values as well as different data used by theController. These t
www.cmccontrols.com224.0 Menu FUNCTION4.1 E-STOP functionPrincipleThe E-stop function could be used for the Emergency stop or for any other particula
23Menu FUNCTION4.2 Time Delay MenuPrincipleWhen the machine process management (motor start and stop) is not synchronized with thecontroller logical
www.cmccontrols.com24Menu FUNCTION4.3 HOLD functionPrincipleThe Hold function can be used by the operator for the machine settings (out of regulation
25Menu FUNCTION4.4 InertiaThis menu is available for open loop configuration when inertia compensation is required.Inertia compensation functionThe i
www.cmccontrols.com26Menu FUNCTION4.5 NO-STOP functionPrincipleThis function is used to manage two independent outputs (one which is the calculation
275.0 Menu PID5.1 Coefficients MenuThis menu is available for both closed loop and inertia compensation configurations. 5.2 Closed loop + Open loop
www.cmccontrols.com285.0 Menu PID5.4 PID MenuPrincipleThe P.I.D. is the heart of the controller calculation system when using the Closed loop mode.P
295.0 Menu PID5.5 MotorThis menu is available in motor command configuration. Tension control for motorized rewinder in speed regulation.In this case
3DIMENSIONS - FIXING166111152381004Front panelcutout1561011 - 5 mmanalogoutputssetpointtacho /diametermeasurementssupplyoutputcontrolalarmslogicinputs
6.0 Menu OUTPUTS6.1 Working rangePrincipleThis function defines the two limits for the actual regulation voltage output AO1 (or AO1 andAO2 when using
Menu OUTPUTS6.2 DISPLAY output function (AO2)This function is used to select one of the following four items to be displayed:-Set point (0 to 10V = w
Menu OUTPUTS6.3 Current limitationPrincipleThis function limits the current in the coil when using EMAG brakes and EMAG clutches directly.As the supp
Menu OUTPUTS6.4 ALARM management functionPrincipleTwo digital outputs have been designed to provide two different alarm signals:Regulation fault: Wh
7.0 Digital Inputs7.1 Digital Inputs A and BPrincipleThe digital inputs A and B are dedicated to the management of the controller’s global status. Itp
Digital Inputs7.2 Logical inputs Reg and InitPrincipleThe digital inputs Reg and Init are dedicated to the management of the P.I.D. calculationprocess
8.0 Data Capture8.1 DATA CAPTURE MenuStarting a Data CaptureThe PC software includes a Data capture function, allowing to visualize and to record each
7550 HUB PARKWAYCLEVELAND, OH 44125216.524.8800 or 800.321.8072www.cmccontrols.comMAN-70421
www.cmccontrols.com4SETTING UPKeypad : Follow -> Input > Measure > ... (load cells)Follow -> Input > Diameter > ... (USsensor)2 - Se
5TYPICAL APPLICATION EXAMPLESWIRING UNWIND WITH EMAG BRAKE AND ULTRASONIC SENSOROPEN LOOPCom+24C1C2V+ABV+InitRegComDM+24+24 VAC / DCEMAGBrakeUltrasoni
www.cmccontrols.com6Initial set of parametersFile : Dancer.prmMachine / product stopped : B = 0V (OPEN)Web Tension = HOLD value (Open Loop)Machine / p
7Machine / product stopped : B = 0V (OPEN)Web Tension = HOLD value (Open Loop)Machine / product running : B = 24V (CLOSED)Web Tension = SET POINT valu
www.cmccontrols.com8Machine / product stopped : B = 0V (OPEN)Web Tension = HOLD value (Open Loop)Machine / product running : B = 24V (CLOSED)Web Tensi
BKRWHLoad cellClassic10 kΩ10 kΩS1-ComS1++5VOTHER LOAD CELL CONFIGURATIONSWiringBKRWHBKRWHLoad cellClassicLoad cellClassicS1-ComS1++5VFull bridgeLoad c